Development of Quality Indicators for the Ultrasound Department through a Modified Delphi Method

30
0
2023-12-19 17:52
MDPI
PTLv2
Followers:3Columns:927

1. Introduction

Imaging services wield substantial influence on patient care across all hospital departments. Ultrasound, recognized for its cost-effectiveness and absence of ionizing radiation, stands as a pervasive diagnostic tool in medical practice, offering broad disease detection capabilities. The escalating demand for ultrasound examinations within public health services and clinical realms underscores the imperative for rigorous quality assurance within ultrasound departments. Moreover, the proficiency of sonographers exhibits significant variability across diverse hospital settings and medical domains, largely contingent upon individual expertise [1]. The absence of standardized protocols for quantitatively assessing ultrasound quality leads to inconsistent examination performance. Consequently, there exists a pressing necessity to formulate precise quality metrics capable of robustly evaluating current ultrasound quality standards and steering enhancements in this field.

Quality indicators serve as pivotal tools catering to the requirements of healthcare performance assessment [2,3,4]. Incorporating these indicators into continuous improvement strategies has the potential to raise the standards of ultrasound services. This integration aims not only to enhance quality and service provisions but also to mitigate healthcare disparities, foster uniformity in quality, and ultimately align with the overarching goal of delivering high-quality healthcare services [5,6].

A large sample [7] assessed the variability of quality and productivity metrics commonly utilized by academic radiology departments and reported some useful indicators such as critical results reporting, relative value unit productivity, emergency department turnaround time, and inpatient imaging turnaround time. Harvey et al. [8] provided examples of performance indicators for radiology, such as compliance with equipment maintenance, technologist-to-scanner ratio, error rates for labeling of images, and staff use rates. Sarwar et al. [9] listed some metrics in radiology, including patient access time, equipment staffing level, equipment idle time, percentage of registered technologists, percentage of complications, etc. While prior studies have established quality indicators beneficial for radiology departments, challenges persist in directly applying these indicators within ultrasound departments. The practicality and feasibility of implementing these indicators in clinical practice within the ultrasound domain present significant hurdles, potentially limiting their seamless integration.

Acknowledging the escalating awareness regarding the adverse impact of ultrasound errors on patient outcomes, the imperative for continual enhancement in ultrasound services remains paramount. This study aims to establish a comprehensive set of pertinent and viable ultrasound quality indicators. By synthesizing insights from the literature, expert consensus, and real-world hospital applications, these indicators are expected to evaluate the current quality landscape and foster improvements in ultrasound performance. The ultimate goal is to ensure precise disease diagnosis and treatment efficacy in the future.

2. Materials and Methods

2.1. The Development of Indicators

The process of developing ultrasound quality indicators included a literature review followed by a three-round modified Delphi consensus process (Figure 1).

Figure 1. Stages in the development of ultrasound quality indicators.

2.2. Analysis of Indicators

To ensure the efficacy and practicality of indicators, mainland Chinese hospitals offering ultrasound diagnosis were invited, in collaboration with local governments and health commissions, to partake in a survey. The survey’s objective was to gather data concerning ultrasound indicators and other pertinent information, collected and submitted on an annual basis. Within each participating hospital, a chief or associate chief doctor from the ultrasound department was assigned as the lead. They received specialized training to acquaint themselves with the indicators, oversee the recording and analysis of ultrasound quality data, and subsequently input this data into the NUQCC database (https://www.nuqcc.cn, accessed on 1 April 2023). The baseline data for ultrasound quality indicators in 2020 was sourced from the NUQCC database.

Concurrently, a national administrative directive initiated a comprehensive ultrasound quality improvement program. Following one year of program implementation, 2021 indicator data were obtained from the NUQCC database, mirroring the prior approach. Comparative analyses between the two years assessed changes in quality indicators. Quantitative data were presented as means, while qualitative data were depicted as frequencies. Normal distribution was tested using the Shapiro–Wilk test. Differences in nonparametric data were evaluated via the Mann–Whitney U test, whereas differences in parametric data were assessed using the paired t-test, considering a significance threshold of p-value < 0.05 (SPSS Statistics version 24.0, IBM Corp., Armonk, NY, USA).

3. Results

3.1. Literature Review

A literature search was executed to pinpoint potentially relevant indicators from medical imaging indicator research and governmental documents focusing on existing medical quality indicators [7,8,9,10,11,12,13,14,15,16,17,18,19,20]. Following a comprehensive review of full-text manuscripts, a total of seven indicators were identified and summarized. These comprised three structure indicators, two process indicators, and two outcome indicators.

3.2. Assembling a Work Team

The work team consisted of six ultrasound experts, among whom three held administrative positions, complemented by an experienced medical quality manager, a researcher, a member of the medical service department, and a policy-maker. Collaboratively, the team meticulously reviewed the initial draft indicators, ultimately including a total of seven candidate indicators following an iterative review process (as presented in . The refinement process involved summarizing references and implementing minor adjustments in wording and explanations.

The work team also devised specific criteria for the expert panels to consider when evaluating and providing feedback on the candidate indicators [21,22,23]: (1) importance: ensuring the indicators encapsulate crucial facets of ultrasound practice, (2) validity: assessing the indicators’ representation within the comprehensive framework, and (3) feasibility: ensuring that the information required for submission is readily accessible and easy to collect.

3.3. Multistage Consensus

Thirty-six experts constituted the panel. The response rates in round 1, round 2 and round 3 were 75% (n = 27), 100% (n = 36) and 92% (n = 33), respectively. In round 1, a questionnaire containing seven indicators was presented to the expert panel. Six (86%) indicators (except the positive rate) reached consensus . Additionally, we also received opinions and concerns about indicators and other highly proposed indicators.

During Round 2, the expert panel engaged in face-to-face discussion conferences to evaluate the Round 1 results, exchange perspectives, and delve into detailed discussions on any concerns. This forum facilitated further refinement and development of several indicators through comprehensive discussions. Subsequently, following Round 2, a refined set of 13 indicators spanning three domains was finalized. These revised indicators formed the basis of the questionnaire that would be circulated to experts for Round 3 evaluation.

During Round 3, the expert panel reviewed the outcomes of the sample survey embedded within the questionnaire, reassessing the 13 indicators through personalized email correspondence, and applying the same criteria as utilized in Round 1. presents the conclusive ratings for each indicator. Following two Delphi rounds and discussion conferences, consensus was achieved on 13 ultrasound performance quality indicators. These encompassed two structure indicators, three process indicators, three general outcome indicators, and five disease-specific outcome indicators, as outlined in , and further details are shown in the .

3.4. Applications of Indicators in Chinese Hospitals

The implemented national ultrasound quality improvement program encompassed initiatives such as promoting standardized ultrasound scan protocols, establishing definitions for ultrasound quality indicators, and implementing quality control management standards. This program was executed through various channels, including annual national conferences on ultrasound quality control, web-based training sessions, and quarterly departmental quality control meetings. Notably, the voluntary enrollment count for hospitals participating in the program amounted to 7043 in 2020 and increased to 7095 in 2021.

The average monthly workload per sonographer was 570.30 in 2020 and 623.37 in 2021 (p < 0.05). The ultrasound instrument quality inspection rate was 94.65% in 2020 and 97.19% in 2021 (p < 0.001). The completion rate of inpatient ultrasound examinations within 48 h was 93.27% in 2020 and 96.33% in 2021 (p = 0.015). The qualification rate of ultrasound reports was 96.38% in 2020 and 98.51% in 2021 (p = 0.002). The accuracy rate of ultrasound diagnosis of breast lesions was 73.53% in 2020 and 82.46% in 2021 (p < 0.001). The incidence of major complications associated with ultrasound-guided interventions was 0.37% in 2020 and 0.89% in 2021 (p = 0.001).

Other quality indicators did not show significant differences, as shown in . The completion rate of notification of ultrasound critical findings within 10 min was 94.89% in 2020 and 97.91% in 2021 (p = 0.050). The positive rate of outpatient and emergency ultrasound examinations (2020 vs. 2021: 71.50% vs. 70.59%, p = 0.499) was very close. The positive rate of inpatient ultrasound examinations (2020 vs. 2021: 77.76% vs. 76.46%, p = 0.421) was very close too. The coincidence rate of ultrasound diagnoses was 73.53% in 2020 and 82.46% in 2021 (p = 0.676). The BI-RADS utilization rate for breast lesions in ultrasound reports was 81.78% in 2020 and 79.52% in 2021 (p = 0.436). The detection rate of fatal fetal malformations in ultrasound screening for pregnant women was 0.06% in 2020 and 0.07% in 2021 (p = 0.149). The analysis of the “coincidence rate of ultrasound diagnosis of ≥50% carotid stenosis” is excluded due to the lack of empirical data.

4. Discussion

This study developed a set of ultrasound quality indicators using a modified Delphi method by the national expert panel. Utilizing the anonymous Delphi methodology, which fosters candid responses and consolidates collective expert opinions, has gained widespread acceptance across diverse healthcare domains [24,25,26]. The engagement and feedback from the expert panel underscored the importance of quality assessment and emphasized the necessity for constructing quality indicators to evaluate ultrasound performance.

Ondategui-Parra et al. [11] investigated prevalent management performance indicators in academic radiology departments within the USA, identifying six categories encompassing 28 performance indicators, such as ‘productivity, reporting, access, satisfaction, and finance’. Similarly, Karami et al. [16] developed a comprehensive set of 92 indicators for academic radiology departments using the Delphi method. These indicators were categorized into seven main domains, including ‘safety, service, internal and external customers, teaching and research, resource utilization, financial performance, and workplace excellence’. Our study proposes thirteen quality indicators for ultrasound departments, comprising two structure indicators, three process indicators, three general outcome indicators, and five disease-specific outcome indicators. These indicators hold applicability across various levels, spanning from individual, sectional, and departmental levels to the broader hospital, provincial, and national levels. This broad scope serves to enhance awareness and facilitate quality improvement initiatives. Furthermore, these indicators may facilitate inter-institutional comparisons, track alterations over time, and ascertain the efficacy of implemented actions in driving improvement.

Among two structure indicators, the quality indicator ‘average monthly workload per sonographer’ assesses the adequacy of human resource allocation and organizational structure essential for delivering quality care. Maintaining appropriate staffing levels and manageable workloads is crucial for upholding ultrasound quality [27]. Excessive workloads pose the risk of incomplete studies, emphasizing the importance of not just ‘quantity’ but also ‘quality’ in performance. The quality indicator ‘ultrasound instruments quality inspection rate’ serves as a vital criterion to evaluate ultrasound equipment quality and safety. Malfunctioning or obsolete equipment may compromise image quality. Regular inspection and maintenance are pivotal to ensuring optimal equipment performance, thus safeguarding the production of high-quality images crucial for accurate interpretation [28].

Among the three process indicators, the quality indicator ‘completion rate of inpatient ultrasound examinations within 48 h’ offers valuable insights into the influx of examination requests and the ultrasound department’s capacity to manage them, reflecting the overall accessibility of medical resources. Timely examinations play a crucial role in early diagnosis, preventing patient deterioration, reducing hospital stays, enhancing overall efficiency, and curbing costs [13]. Unlike outpatient settings, where examination timing might align with patient convenience, inpatient examinations prioritize urgency based on clinical necessity. The quality indicator ‘completion rate of notification of ultrasound critical findings within 10 min’ safeguards the prompt reporting of critical ultrasound findings. Critical findings encompass new or unexpected discoveries that could lead to severe morbidity or mortality without appropriate diagnostic or therapeutic interventions [29]. Efficient and timely communication is paramount for patient safety in such instances, while inadequate communication can lead to serious adverse events.

The quality indicator ‘qualification rate of ultrasound reports’ mirrors the quality standards upheld within ultrasound examination reports. A qualified report is characterized by clarity, accuracy, confidence, conciseness, completeness, and consistency [30]. Errors within ultrasound reports, such as missing outpatient or hospitalization numbers, clinical diagnoses, measurement data, sex-related errors, or incorrect orientations, can provoke patient complaints and precipitate medical disputes.

In general outcome indicators, the quality indicator “positive rate of outpatient and emergency ultrasound examinations” and quality indicator “positive rate of inpatient ultrasound examinations” are parameters that should be taken into consideration while assessing the accuracy of ultrasound diagnosis. These rates reflect both the appropriateness of clinicians’ prescription of ultrasound examinations and the accuracy of the results obtained. The positive rate is influenced by not only the pretest probabilities of patients having a disease but also by the proficiency of sonographers and the quality of referrals. Clinicians play a crucial role in understanding examination indications, reducing unnecessary or repetitive tests, and preventing the misuse of medical resources. Simultaneously, sonographers must continually enhance their professional expertise and technical skills to avert false-negative diagnoses arising from incomplete or insufficient scans. It is important to note that hospitals dealing primarily with complex cases might display lower coincidence rates in ultrasound examinations compared to those handling simpler cases. However, it is unjustifiable to infer inferior service quality based solely on this comparison. Consequently, these indicators constitute an indispensable and significant component of ultrasound quality evaluation. Patient preconditions can significantly differ across various sectors and hospitals of distinct tiers, such as ultrasound outcomes in medical check-up centers versus those in emergency departments, where, generally, the positive rate of emergency department ultrasound examinations tends to be higher. The quality indicator ‘coincidence rate of ultrasound diagnoses’ holds significant value in assessing the quality of ultrasound diagnosis, primarily reflecting the diagnostic accuracy within a specified period in an ultrasound department. Incorrect diagnoses, such as misdiagnosing breast cancer as a benign lesion, can lead to delayed treatment, exacerbating the patient’s condition and potentially escalating fatality risks. Hence, it is imperative for sonographers to furnish patients and clinicians with reports that exhibit high accuracy in interpretation.

The disease-specific outcome indicators, tailored for diseases suitable or preferable for ultrasound examinations like breast lesions, vascular diseases, and prenatal screening, garnered significant interest. Consequently, the quality indicators ‘BI-RADS utilization rate for breast lesions in ultrasound reports,’ ‘accuracy rate of ultrasound diagnosis of breast lesions,’ ‘detection rate of fatal fetal malformations in ultrasound screening for pregnant women,’ ‘coincidence rate of ultrasound diagnosis of ≥50% carotid stenosis,’ and ‘incidence of major complications associated with ultrasound-guided interventions’ attained consensus. The corresponding definitions for these indicators are delineated in . These disease-specific outcome indicators offer a more detailed reflection of ultrasound quality and pinpoint specific avenues for directing our quality improvement efforts. Nevertheless, we regard our study as an inaugural phase in an ongoing progression. It is evident that additional quality indicators reflecting the performance of ultrasound across various domains need development and practical implementation to enrich the field and enhance the standard of ultrasound practice.

The data analysis of quality indicators in nationwide hospital implementation demonstrated their feasibility and interpretability to a certain extent. The rise in average monthly workload per sonographer highlighted an escalating demand for ultrasound examinations, signaling the necessity for further investigations to establish optimal staff allocation. This pursuit aims to achieve rational human resource utilization and avert performance issues arising from excessive workloads. The increased ultrasound instruments’ quality inspection rate suggested the timely replacement of equipment that failed quality control tests, and indicated a proactive approach to replacing equipment failing quality control assessments. This contributes significantly to governing ultrasound equipment usage, monitoring image quality, and curbing errors linked to inadequate images. The significant enhancement in the accuracy rate of ultrasound diagnosis of breast lesions indicated improved adherence to standardized ultrasound examination protocols by sonographers. It also signified an enhanced capability to make precise diagnoses after the quality improvement program. The increased qualification rate of ultrasound reports suggested a decline in errors within reports, emphasizing the importance of objectively detailing ultrasound examination information to facilitate effective communication. The improvement in the completion rate of inpatient ultrasound examinations within 48 h suggested an augmented capacity among sonographers, even amidst increased workload demands, resulting in reduced patient waiting times.

Additionally, the changes in the incidence of major complications associated with ultrasound-guided interventions pointed out that corresponding quality improvement programs for ultrasound-guided interventions should be considered to ensure patient safety in the future. The little significance of other quality indicators (including completion rate of notification of ultrasound critical findings within 10 min, detection rate of fatal fetal malformations in ultrasound screening for pregnant women, BI-RADS utilization rate for breast lesions in ultrasound reports, positive rate of outpatient and emergency ultrasound examinations, positive rate of inpatient ultrasound examinations, and coincidence rate of ultrasound diagnoses) can be explained by subtle changes in the pretest probability of corresponding disease prevalence or limited progression in relative skills of sonographers produced by the former quality improvement program. This also reminded us that underlying reasons and better improvement methods need to be further studied in the future.

It is intriguing to compare the findings of Tao et al. [31], who utilized eight quality indicators to assess the impact of a national ultrasound quality improvement program, with our study’s outcomes. Our study aimed to develop ultrasound control indicators, whereas their research focused on implementing a quality improvement program and evaluating its effectiveness. Meanwhile, their results indicated that the program led to improved accuracy in ultrasound diagnosis and highlighted an increasing demand for ultrasound examinations, signaling the necessity for more ultrasound practitioners. In contrast, our study, focusing on disease-specific quality indicators, specifically identifies the areas where ultrasound diagnosis accuracy has been enhanced. Furthermore, the changes observed in process indicators offer insights into specific workflow areas that necessitate improvement. This distinction in focus between disease-specific indicators and process indicators provides a more nuanced understanding of the improvements resulting from the quality improvement program. Both approaches, Tao et al.’s broader assessment and our study’s specific focus, contribute to comprehensively evaluating the impact and areas for refinement in ultrasound quality initiatives.

Thus, the results provide some evidence, and it can be preliminarily judged that these quality indicators are likely to monitor changes in ultrasound quality, reflect meaningful information about deficiencies, and guide quality improvement measures to improve quality when poor performance is observed. Nevertheless, this study analyzed the application of the quality indicators over a 2-year period, which may not be long enough to completely validate whether changes in indicators reflect true changes in quality. For participating hospitals, how the data are interpreted and how data interpretation can lead to quality improvement are of major concern. Further approaches to address the validity of the data, evaluate the feasibility of data collection and sensitivity to change, and examine discriminatory power are warranted in future implementations.

While this study demonstrates the first effort to develop quality indicators for the ultrasound department, there are some limitations. First, there is a lack of indicators of research and education, costs, and the value of other stakeholders such as patients and referring physicians. Future efforts should focus on drilling down to obtain further detail. Second, our study demonstrates the establishment of ultrasound quality control indicators and the initial results of the application of the indicators. The optimal and suboptimal threshold of agreed-upon indicators need to be determined in further research. Third, this is a study based on national but not international experts. We also look forward to future collaborations with international experts to establish quality indicators that are broadly applicable to ultrasound medicine in most countries.

5. Conclusions

Our study developed 13 ultrasound quality indicators through a literature review and national expert consensus-building. Implementation across multiple hospitals nationwide demonstrated that 13 ultrasound quality indicators can effectively accomplish continuous data collection and faster assessment. These ultrasound quality indicators serve as a valuable framework for assessing ultrasound practice, empowering hospitals and sonographers to deliver high-quality healthcare services. It also encourages more effective management strategies, paving the way for improved healthcare standards in the future.

References

  1. Caserta, M.P.; Bonnett, S.L.; La Valley, M.C.; De Meo, S.; Bowman, A.W. Ultrasound Practice Redesign to Improve Image Quality: Implementation of a Quality Control Sonographer. J. Am. Coll. Radiol. 2020, 17, 1644–1652. [Google Scholar] [CrossRef] [PubMed]
  2. Sreedher, G.; Ho, M.-L.; Smith, M.; Udayasankar, U.K.; Risacher, S.; Rapalino, O.; Greer, M.-L.C.; Doria, A.S.; Gee, M.S. Magnetic resonance imaging quality control, quality assurance and quality improvement. Pediatr. Radiol. 2021, 51, 698–708. [Google Scholar] [CrossRef]
  3. OECD/WHO. Improving Healthcare Quality in Europe: Characteristics, Effectiveness and Implementation of Different Strategies; OECD Publishing: Paris, France, 2019. [Google Scholar] [CrossRef]
  4. Nelson, J.; Ding, A.; Mann, S.; Parsons, M.; Samei, E. Key Performance Indicators for Quality Imaging Practice: Why, What, and How. J. Am. Coll. Radiol. 2022, 19 Pt A, 4–12. [Google Scholar] [CrossRef]
  5. Steele, J.R.; Schomer, D.F. Continuous quality improvement programs provide new opportunities to drive value innovation initiatives in hospital-based radiology practices. J. Am. Coll. Radiol. 2009, 6, 491–499. [Google Scholar] [CrossRef] [PubMed]
  6. Flug, J.A.; Stellmaker, J.A.; Sharpe, R.E.; Jokerst, C.E.; Tollefson, C.D.; Bowman, A.W.; Nordland, M.; Hannafin, C.L.; Froemming, A.T. Kaizen Process Improvement in Radiology: Primer for Creating a Culture of Continuous Quality Improvement. Radiographics 2022, 42, 919–928. [Google Scholar] [CrossRef] [PubMed]
  7. Walker, E.A.; Petscavage-Thomas, J.M.; Fotos, J.S.; Bruno, M.A. Quality metrics currently used in academic radiology departments: Results of the QUALMET survey. Br. J. Radiol. 2017, 90, 20160827. [Google Scholar] [CrossRef] [PubMed]
  8. Harvey, H.B.; Hassanzadeh, E.; Aran, S.; Rosenthal, D.I.; Thrall, J.H.; Abujudeh, H.H. Key Performance Indicators in Radiology: You Can’t Manage What You Can’t Measure. Curr. Probl. Diagn. Radiol. 2016, 45, 115–121. [Google Scholar] [CrossRef]
  9. Sarwar, A.; Boland, G.; Monks, A.; Kruskal, J.B. Metrics for Radiologists in the Era of Value-based Health Care Delivery. Radiographics 2015, 35, 866–876. [Google Scholar] [CrossRef]
  10. Tossaint-Schoenmakers, R.; Versluis, A.; Chavannes, N.; Talboom-Kamp, E.; Kasteleyn, M. The Challenge of Integrating eHealth Into Health Care: Systematic Literature Review of the Donabedian Model of Structure, Process, and Outcome. J. Med. Internet Res. 2021, 23, e27180. [Google Scholar] [CrossRef]
  11. Ondategui-Parra, S.; Bhagwat, J.G.; Zou, K.H.; Gogate, A.; Intriere, L.A.; Kelly, P.; Seltzer, S.E.; Ros, P.R. Practice management performance indicators in academic radiology departments. Radiology 2004, 233, 716–722. [Google Scholar] [CrossRef]
  12. Abujudeh, H.H.; Kaewlai, R.; A Asfaw, B.; Thrall, J.H. Quality initiatives: Key performance indicators for measuring and improving radiology department performance. Radiographics 2010, 30, 571–580. [Google Scholar] [CrossRef] [PubMed]
  13. Radiology ACo. Practice Guidelines and Technical Standards. 2013. Available online: http://www.acr.org/Quality-Safety/Standards-Guidelines (accessed on 1 May 2023).
  14. Burstin, H.; Leatherman, S.; Goldmann, D. The evolution of healthcare quality measurement in the United States. J. Intern. Med. 2016, 279, 154–159. [Google Scholar] [CrossRef] [PubMed]
  15. European Society of Radiology (ESR); American College of Radiology (ACR). European Society of Radiology (ESR) and American College of Radiology (ACR) report of the 2015 global summit on radiological quality and safety. Insights Imaging 2016, 7, 481–484. [Google Scholar] [CrossRef]
  16. Karami, M. Development of key performance indicators for academic radiology departments. Int. J. Healthc. Manag. 2016, 10, 275–280. [Google Scholar] [CrossRef]
  17. Marriner, M. Sonographer quality management. J. Echocardiogr. 2020, 18, 44–46. [Google Scholar] [CrossRef]
  18. Harden, S.V.; Chiew, K.L.; Millar, J.; Vinod, S.K. Quality indicators for radiation oncology. J. Med. Imaging Radiat. Oncol. 2022, 66, 249–257. [Google Scholar] [CrossRef]
  19. Teichgräber, U.; Sibbel, R.; Heinrich, A.; Güttler, F. Development of a balanced scorecard as a strategic performance measurement system for clinical radiology as a cost center. Insights Imaging 2021, 12, 69. [Google Scholar] [CrossRef]
  20. DiCostanzo, D.J.; Kumaraswamy, L.K.; Shuman, J.; Pavord, D.C.; Hu, Y.; Jordan, D.W.; Waite-Jones, C.; Hsu, A. An introduction to key performance indicators for medical physicists. J. Appl. Clin. Med. Phys. 2022, 23, e13718. [Google Scholar] [CrossRef] [PubMed]
  21. Schang, L.; Blotenberg, I.; Boywitt, D. What makes a good quality indicator set? A systematic review of criteria. Int. J. Qual. Health Care 2021, 33, mzab107. [Google Scholar] [CrossRef]
  22. Barbazza, E.; Klazinga, N.S.; Kringos, D.S. Exploring the actionability of healthcare performance indicators for quality of care: A qualitative analysis of the literature, expert opinion and user experience. BMJ Qual. Saf. 2021, 30, 1010–1020. [Google Scholar] [CrossRef]
  23. Gartner, J.B.; Lemaire, C. Dimensions of performance and related key performance indicators addressed in healthcare organisations: A literature review. Int. J. Health Plann. Manage 2022, 37, 1941–1952. [Google Scholar] [CrossRef]
  24. Boulkedid, R.; Abdoul, H.; Loustau, M.; Sibony, O.; Alberti, C. Using and reporting the Delphi method for selecting healthcare quality indicators: A systematic review. PLoS ONE 2011, 6, e20476. [Google Scholar] [CrossRef]
  25. Nasa, P.; Jain, R.; Juneja, D. Delphi methodology in healthcare research: How to decide its appropriateness. World J. Methodol. 2021, 11, 116–129. [Google Scholar] [CrossRef]
  26. Granata, V.; Morana, G.; D’Onofrio, M.; Fusco, R.; Coppola, F.; Grassi, F.; Cappabianca, S.; Reginelli, A.; Maggialetti, N.; Buccicardi, D.; et al. Structured Reporting of Computed Tomography and Magnetic Resonance in the Staging of Pancreatic Adenocarcinoma: A Delphi Consensus Proposal. Diagnostics 2021, 11, 2033. [Google Scholar] [CrossRef]
  27. Alexander, R.; Waite, S.; Bruno, M.A.; Krupinski, E.A.; Berlin, L.; Macknik, S.; Martinez-Conde, S. Mandating Limits on Workload, Duty, and Speed in Radiology. Radiology 2022, 304, 274–282. [Google Scholar] [CrossRef]
  28. Wang, L.; Li, B.; Hu, B.; Shen, G.; Zheng, Y.; Zheng, Y. Failure mode effect and criticality analysis of ultrasound device by classification tracking. BMC Health Serv. Res. 2022, 22, 429. [Google Scholar] [CrossRef]
  29. Mabotuwana, T.; Hall, C.S.; Cross, N. Framework for Extracting Critical Findings in Radiology Reports. J. Digit. Imaging 2020, 33, 988–995. [Google Scholar] [CrossRef]
  30. Nobel, J.M.; van Geel, K.; Robben, S.G.F. Structured reporting in radiology: A systematic review to explore its potential. Eur. Radiol. 2022, 32, 2837–2854. [Google Scholar] [CrossRef]
  31. Tao, X.; Li, J.; Gu, Y.; Ma, L.; Xu, W.; Wang, R.; Gao, L.; Zhang, R.; Wang, H.; Jiang, Y. A National Quality Improvement Program on Ultrasound Department in China: A Controlled Cohort Study of 1297 Public Hospitals. Int. J. Environ. Res. Public Health 2022, 20, 397. [Google Scholar] [CrossRef]
Related Suggestion
Ultrasound Features and Clinical Outcome of Patients with Ovarian Masses Diagnosed during Pregnancy: Experience of Single Gynecological Ultrasound Center
Clinical
(1) Background: The number of adnexal masses detected during pregnancy has increased due to the use of first-trimester screening and increasingly advanced maternal age. Despite their low risk of malignancy, other risks associated with these masses include torsion, rupture and labor obstruction. Correct diagnosis and management are needed to guarantee both maternal and fetal safety. Adnexal masses may be troublesome to classify during pregnancy due to the increased volume of the uterus and pregnancy-related hormonal changes. Management should be based on ultrasound examination to provide the best treatment. The aim of this study was to describe the ultrasound features of ovarian masses detected during pregnancy and to optimize and personalize their management with the expertise of gynecologists, oncologists and sonographers. (2) Methods: Clinical, ultrasound, histological parameters and type of management (surveillance vs. surgery) were retrospectively retrieved. Patient management, perinatal outcomes and follow-up were also evaluated. (3) Results: according to the literature, these masses are most frequently benign, ultrasound follow-up is the best management, and obstetric outcomes are not considerably influenced by the presence of adnexal masses. (4) Conclusions: the management of patients with ovarian masses detected during pregnancy should be based on ultrasound examination, and a centralization in referral centers for ovarian masses should be considered.
531
0
Concurrent Imaging and Clinical Study of the Efficacy of Hyaluronic Acid Injection for Knee Osteoarthritis: A Synovial Membrane Investigation with Ultrasound Imaging
Clinical
We investigated whether hyaluronic acid (HA) injections can ameliorate ultrasound-detected synovitis in knee osteoarthritis (OA). We recruited 103 patients with symptomatic knee OA and ultrasound-detected synovitis and performed two ultrasound-guided fluid drainage procedures, followed by the administration of a low-molecular-weight HA injection (2.5 mL) in the subpatellar bursa, at a 2-week interval. Knee ultrasound imaging evaluations were performed before injection (baseline) and at 1 and 6 months after the second injection and included the measurements of synovial vascularity by using color Doppler ultrasound, synovial fluid depth over the suprapatellar bursa (SF), and synovial hypertrophy (SH). Initial clinical assessments included a visual analog scale (VAS) and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). VAS scores decreased significantly at both 1-month and 6-month evaluations (p < 0.001). WOMAC scores also significantly decreased at 1 month (p < 0.001), but not at 6 months (p = 0.23). The ultrasound parameters did not significantly change, except color Doppler grading, which tended to decrease at the 6-month evaluation (p = 0.059). Our findings revealed that two ultrasound-guided HA injections following fluid drainage improved pain and knee function but did not considerably influence imaging-detected synovitis in patients with knee OA.
152
0
Ultrasound-Treated and Thermal-Pasteurized Hawthorn Vinegar: Antioxidant and Lipid Profiles in Rats
Information
The hawthorn fruit, a member of the Rosaceae family, is a medicinal plant with numerous therapeutic properties. It has a wide range of variants, with Crataegus tanacetifolia being the most widely recognized species in the world. The hawthorn fruit has various biological activities, including anti-inflammatory, antibacterial, antioxidant, immune-modulating, and anti-carcinogenic properties. This study focused on improving the antioxidant activity of hawthorn vinegar via different methods. We also aimed to investigate the influence of its hepatic antioxidant abilities on health and extend the shelf life of the vinegar. In the study, the vinegar was produced from the hawthorn fruit, and thermal pasteurization and ultrasound techniques were applied. A total of 56 female adult Wistar-Albino rats were allocated into seven groups and administered hawthorn fruit vinegar via oral gavage on a daily basis. The experimental groups included rats treated with pasteurized vinegar (HVP), ultrasound-treated rats (HVU), and an untreated group that received regular vinegar (HVN) at two different dosage levels (0.5 and 1 mL/kg). The SOD, MDA, and CAT antioxidant levels were measured using the ELISA method in plasma and liver tissue samples. The total plasma cholesterol, triglyceride, HDL, LDL, AST, and ALT values were quantified using commercially available kits. The levels of SOD and CAT in the plasma and liver were found to be significantly higher in the HVU1 group compared to all other groups. Furthermore, the HVU1 cohort exhibited the highest HDL value in plasma. The plasma LDL levels were comparably low in both the thermal-pasteurized and ultrasound-treated groups. There were significant expressions of both CAT and SOD in the liver tissues of the HVU groups (analyzed immunohistochemically). These results indicated that hawthorn vinegar administration with 1 mL/kg in group HVU1 could significantly enhance antioxidant capacity in the liver and, consequently, overall health. It can be suggested that the possible therapeutic effect
146
0
Comments 0
Please to post a comment~
Loading...
Likes
Send-Pen
Favorites
Comment